Operation
14
Service Instructions for Your Heating System
Viessmann strongly recommends inspection/service of the boiler and the system by a
licensed professional heating contractor once per year.
Before the heating season begins, the boiler with its burner(s) and vent system should be
serviced by a qualified heating contractor. Service contracts may be established through
gas suppliers or other licensed contractors in your area.
Regular inspection/service ensures troublefree, energy-efficient and environmentally
friendly heating activity of your heating system.
Boiler
All boilers must be cleaned on a regular
basis as debris build-up will result in
increased flue gas temperature, and thus
in increased energy consumption.
Notes on operation:
H Ensure boiler room and boiler
are clean.
H Regularly check heating system
pressure on the pressure gage:
If the system o perating pressure
gage is indicating a pressure of
below 14 psig, the system pressure
is to o low; in this case, please
contact your heating contractor.
Viessmann domestic hot water storage
tank
Inspection and (if necessary) cleaning of
the tank must take place within 2 years of
initial start-up and every 2 years
thereafter.
Cleaning of the inside surfaces of the
domestic hot water storage tank, including
domestic hot water connections, may only
be performed by an licensed professional
heating contractor.
Vitocell 100:
Viessmann recommends an annual
inspection, and replacement if required, of
the consumable anode by a licensed
professional heating contractor.
The inspection can be carried out during
regular operation of the heating system;
shut-down is not required.
The heating contractor measures the
protective current with an anode testing
instrument.
If a water treatment device (water
softener) is installed in the domestic cold
water supply to the hot water storage
tank, ensure its proper working condition
is checked regularly by your heating
contractor.
The same applies if a dirt trap or a water
filter is installed in the domestic cold
water supply. Any of these devices
installed in the domestic cold water supply
must be flushed out and serviced on a
regular basis.
Drinking water filter (if installed)
For hygienic reasons
H replace filter element every
6 months on filters which cannot be
flushed back, and perform a visual
inspection every 2 months,
H flush back reversible flow filters
every 2 months.
Please follow manufacturer’s
instructions.
5581 532 v1.1
IMPORTANT