© Viessmann 5443203
| 22
SCU224
System layout 7
The controller calculates the temperature differences
between the collector sensors S1 and S3 and the tank
sensor S2. If the differences are larger than or identical to
the adjusted switch-on temperature difference (DT O), the
respective solar pump will be operated by relay 1 and / or
R1
R2
S1
S2
S3
Arr 7
Display Channels
Channel Description Terminal Page
COL1 x Temperature collector 1 S1 37
TST x Temperature tank S2 37
COL2 x Temperature collector 2 S3 37
S4 x Temperature sensor 4 S4 37
n1 % x Pump speed R1 R1 38
n2 % x Pump speed R2 R2 38
h P1 x Operating hours R1 R1 38
h P2 x Operating hours R2 R2 38
TIME x Time - 34
relay 2, and the tank will be loaded until the switch-off
temperature difference (DT F) or the maximum tank tem-
perature (S MX) is reached.
Sensor S4 can optionally be connected for measurement
purposes.